Continued versus Suspended Cardiac Resynchronization Therapy after Left Ventricular Assist Device Implantation
Recommended Citation
Roukoz H, Bhan A, Ravichandran A, Ahmed MM, Bhat G, Cowger J, Abdullah M, Dhawan R, Trivedi JR, Slaughter MS, and Gopinathannair R. Continued versus Suspended Cardiac Resynchronization Therapy after Left Ventricular Assist Device Implantation. Sci Rep 2020; 10(1):2573.
Document Type
Article
Publication Date
2-13-2020
Publication Title
Sci Rep
Abstract
Cardiac resynchronization therapy (CRT) improves outcomes in heart failure patients with wide QRS complex. However, CRT management following continuous flow Left Ventricular Assist Device (LVAD) implant vary: some centers continue CRT while others turn off the left ventricular (LV) lead at LVAD implant. We sought to study the effect of continued CRT versus turning off CRT pacing following continuous flow LVAD implantation. A comprehensive retrospective multicenter cohort of 295 patients with LVAD and pre-existing CRT was studied. CRT was programmed off after LVAD implant in 44 patients. We compared their outcomes to the rest of the cohort using univariate and multivariate models. Mean age was 60 ± 12 years, 83% were males, 52% had ischemic cardiomyopathy and 54% were destination therapy. Mean follow-up was 2.4 ± 2.0 years, and mean LVAD support time was 1.7 ± 1.4 years. Patients with CRT OFF had a higher Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) mean profile (3.9 vs 3.3, p = 0.01), more secondary prevention indication for a defibrillator (64.9% vs 44.5%, p = 0.023), and more pre-LVAD ventricular arrhythmias (VA) (77% vs 60%, p = 0.048). There were no differences between the CRT OFF and CRT ON groups in overall mortality (Log rank p = 0.32, adjusted HR = 1.14 [0.54-2.22], p = 0.71), heart transplantation, cardiac and noncardiac mortality, all cause hospitalizations, hospitalizations for ICD shocks, and number and frequency of ICD shocks or anti-tachycardia pacing therapy. There were no differences in post LVAD atrial arrhythmias (AA) (Adjusted OR = 0.45 [0.18-1.06], p = 0.31) and ventricular arrhythmias (OR = 0.65 [0.41-1.78], p = 0.41). There was no difference in change in LVEF, LV end diastolic and end systolic diameters between the 2 groups. Our study suggests that turning off CRT pacing after LVAD implantation in patients with previous CRT pacing did not affect mortality, heart transplantation, device therapies or arrhythmia burden. A prospective study is needed to confirm these findings.
PubMed ID
32054868
Volume
10
Issue
1
First Page
2573
Last Page
2573