Dynamic foraminal dimensions during neck extension and rotation in fusion and artificial disc replacement: an observational study
Recommended Citation
Yeni YN, Baumer T, Oravec D, Basheer A, McDonald CP, Bey MJ, Bartol SW, and Chang V. Dynamic foraminal dimensions during neck extension and rotation in fusion and artificial disc replacement: an observational study. Spine J 2018; 18(4):575-583.
Document Type
Article
Publication Date
4-1-2018
Publication Title
The spine journal
Abstract
BACKGROUND: Changes in the dimensions of the cervical neural foramina (CNF) are considered to be a key factor in nerve root compression and development of cervical radiculopathy. However, to what extent foraminal geometry differs between patients who underwent anterior cervical discectomy and fusion (ACDF) and those who underwent total disc arthroplasty with an artificial disc (AD) during physiological motion is largely unknown.
PURPOSE: The objective of this study is to compare CNF dimensions during physiological neck motion between ACDF and AD.
STUDY DESIGN/SETTING: This is a retrospective comparative analysis of prospectively collected, consecutive, non-randomized series of patients at a single institution.
PATIENT SAMPLE: A total of 16 single-level C5-C6 ACDF (4 males, 12 females; 28-71 years) and 7 single-level C5-C6 cervical arthroplasty patients (3 males, 4 females; 38-57 years), at least 12 months after surgery (23.6±6.8 months) were included.
OUTCOME MEASURES: Patient demographics, preoperative magnetic resonance imaging (MRI)-based measurements of cervical spine degeneration, and 2-year postoperative measurements of dynamic foraminal geometry were the outcome measures.
METHODS: Biplane X-ray images were acquired during axial neck rotation and neck extension. A computed tomography scan was also acquired from C3 to the first thoracic vertebrae. The subaxial cervical vertebrae (C3-C7) were reconstructed into three-dimensional (3D) bone models for use with model-based tracking. Foraminal height (FH) was calculated as the 3D distance between the superior point of the inferior pedicle and the inferior point of the superior pedicle using custom software. Foraminal width (FW) was similarly calculated as the 3D distance between the anterolateral aspect of the superior vertebral body inferior notch and the posterolateral aspect of the inferior vertebral body superior notch. Dynamic foraminal dimensions were quantified as the minimum (FH.Min, FW.Min), the range (FH.Range, FW.Range), and the median (FH.Med, FW.Med) of each trial and then averaged over trials. Mixed model analysis of variance framework was used to examine the differences between ACDF and AD groups. The initial severity of disc degeneration as determined from preoperative MRI images was introduced as covariates in the models.
RESULTS: At the operated level (C5-C6), FH.Med and FH.Range were smaller in ACDF than in AD during axial rotation and neck extension (p
CONCLUSIONS: This study demonstrated decreases in foraminal dimensions and their range for ACDF compared with AD at the operated level. In contrast, it demonstrated increases in the range of foraminal dimensions during motion for ACDF compared with AD at the non-operated segments. Together, these data support the notion that increased mobility at the non-operated segments after ACDF may contribute to a greater risk for adjacent segment degeneration. Because of the significant presence of range variables in the findings, the current data also indicate that a dynamic evaluation is likely more appropriate for evaluation of the differences in foramina between ACDF and AD than a static evaluation.
Medical Subject Headings
Adult; Cervical Vertebrae; Female; Humans; Intervertebral Disc Degeneration; Male; Middle Aged; Postoperative Complications; Range of Motion, Articular; Spinal Fusion; Total Disc Replacement
PubMed ID
28882520
Volume
18
Issue
4
First Page
575
Last Page
583