Herr DJ, Yin H, Allen SG, Bergsma DP, Dragovic A, Dess RT, Matuszak MM, Grubb M, Dominello MM, Movsas B, Kestin LL, Hayman JA, Paximadis PA, Schipper M, and Jolly S. Cardiac and Pulmonary Dosimetric Parameters in Lung Cancer Patients Undergoing Post-Operative Radiation Therapy in the Real-World Setting. Int J Radiat Oncol Biol Phys 2022; 114(3):e374-e375.
Document Type
Conference Proceeding
Publication Date
11-1-2022
Publication Title
Int J Radiat Oncol Biol Phys
Abstract
Purpose/Objective(s): The recently published Lung ART trial reported increased rates of cardiac and pulmonary toxicity in the post-operative radiation therapy arm. It remains unknown whether the dosimetric parameters reported in Lung ART are representative of real-world practice. The purpose of this study is to examine heart and lung dose exposure in patients receiving post-operative radiation therapy for non-small cell lung cancer (NSCLC) across a statewide consortium.
Materials/Methods: From 2012 to 2020, 377 patients at 27 academic and community centers within the Michigan Radiation Oncology Quality Consortium (MROQC) underwent surgical resection followed by post-operative radiation therapy for non-metastatic NSCLC. Demographic and dosimetric data were prospectively collected for these patients. Rates of 3D-CRT and IMRT use were analyzed. Mean heart dose (MHD), heart V5, heart V35, mean lung dose (MLD), lung V20, target volume and minimum dose to 95% PTV were calculated for these patients and the reported dosimetric parameters were stratified by treatment modality.
Results: 51% of patients in this cohort had N2 disease at the time of surgery, 18% had a positive margin. 65.8% of patients were treated with IMRT compared to 32.1% treated with 3D-CRT. Average MHD for all patients was 10.3 Gy, mean Heart V5 was 40.3% and mean heart V35 was 12.6%. Average MLD was 11.2 Gy and mean lung V20 was 18.9%. These dosimetric parameters did not significantly differ based on treatment modality, with MHD and MLD 9.9 Gy and 10.1 Gy, respectively, for patients treated with 3D-CRT compared to 10.6 Gy and 11.8 Gy for patients treated with IMRT.
Conclusion: Cardiac and lung dosimetric parameters for patients receiving post-operative radiation therapy for NSCLC are similar to the dosimetric characteristics reported in Lung ART. The mean heart and mean lung doses observed are slightly lower (MHD 10.3 Gy, MLD 11.2 Gy) compared to Lung ART (MHD 13 Gy, MLD 13 Gy), possibly owing to increased use of IMRT. These data support application of Lung ART's findings outside of the clinical trial setting.