Surgeon Skill and Perioperative Outcomes in Robot-Assisted Partial Nephrectomy

Document Type

Article

Publication Date

7-1-2024

Publication Title

JAMA Netw Open

Abstract

IMPORTANCE: Technical skill in complex surgical procedures may affect clinical outcomes, and there is growing interest in understanding the clinical implications of surgeon proficiency levels.

OBJECTIVES: To determine whether surgeon scores representing technical skills of robot-assisted kidney surgery are associated with patient outcomes.

DESIGN, SETTING, AND PARTICIPANTS: This quality improvement study included 10 urological surgeons participating in a surgical collaborative in Michigan from July 2021 to September 2022. Each surgeon submitted up to 7 videos of themselves performing robot-assisted partial nephrectomy. Videos were segmented into 6 key steps, yielding 127 video clips for analysis. Each video clip was deidentified and distributed to at least 3 of the 24 blinded peer surgeons from the collaborative who also perform robot-assisted partial nephrectomy. Reviewers rated technical skill and provided written feedback. Statistical analysis was performed from May 2023 to January 2024.

MAIN OUTCOMES AND MEASURES: Reviewers scored each video clip using a validated instrument to assess technical skill for partial nephrectomy on a scale of 1 to 5 (higher scores indicating greater skill). For all submitting surgeons, outcomes from a clinical registry were assessed for length of stay (LOS) greater than 3 days, estimated blood loss (EBL) greater than 500 mL, warm ischemia time (WIT) greater than 30 minutes, positive surgical margin (PSM), 30-day emergency department (ED) visits, and 30-day readmission.

RESULTS: Among the 27 unique surgeons who participated in this study as reviewers and/or individuals performing the procedures, 3 (11%) were female, and the median age was 47 (IQR, 39-52) years. Risk-adjusted outcomes were associated with scores representing surgeon skills. The overall performance score ranged from 3.5 to 4.7 points with a mean (SD) of 4.1 (0.4) points. Greater skill was correlated with significantly lower rates of LOS greater than 3 days (-6.8% [95% CI, -8.3% to -5.2%]), EBL greater than 500 mL (-2.6% [95% CI, -3.0% to -2.1%]), PSM (-8.2% [95% CI, -9.2% to -7.2%]), ED visits (-3.9% [95% CI, -5.0% to -2.8%]), and readmissions (-5.7% [95% CI, -6.9% to -4.6%]) (P < .001 for all). Higher overall score was also associated with higher partial nephrectomy volume (β coefficient, 11.4 [95% CI, 10.0-12.7]; P < .001).

CONCLUSIONS AND RELEVANCE: In this quality improvement study on video-based evaluation of robot-assisted partial nephrectomy, higher technical skill was associated with lower rates of adverse clinical outcomes. These findings suggest that video-based evaluation plays a role in assessing surgical skill and can be used in quality improvement initiatives to improve patient care.

Medical Subject Headings

Humans; Nephrectomy; Robotic Surgical Procedures; Clinical Competence; Female; Male; Middle Aged; Surgeons; Quality Improvement; Michigan; Length of Stay; Postoperative Complications; Adult

PubMed ID

39008300

Volume

7

Issue

7

First Page

2421696

Last Page

2421696

Share

COinS