Ideal high sensitivity troponin baseline cutoff for patients with renal dysfunction
Recommended Citation
Limkakeng AT, Jr., Hertz J, Lerebours R, Kuchibhatla M, McCord J, Singer AJ, Apple FS, Peacock WF, Christenson RH, and Nowak RM. Ideal high sensitivity troponin baseline cutoff for patients with renal dysfunction. Am J Emerg Med 2021; 46:170-175.
Document Type
Article
Publication Date
8-1-2021
Publication Title
The American journal of emergency medicine
Abstract
OBJECTIVE: High-sensitivity cardiac troponin assays (hs-cTn) aid in diagnosis of myocardial infarction (MI). These assays have lower specificity for non-ST Elevation MI (NSTEMI) in patients with renal disease. Our objective was to determine an optimized cutoff for patients with renal disease.
METHODS: We conducted an a priori secondary analysis of a prospective FDA study in adults with suspected MI presenting to 29 academic urban EDs between 4/2015 and 4/2016. Blood was drawn 0, 1, 2-3, and 6-9 h after ED arrival. We recorded cTn and estimated glomerular filtrate rate (eGFR) by Chronic Kidney Disease Epidemiology Collaboration equation. The primary endpoint was NSTEMI (Third Universal Definition of MI), adjudicated by physicians blinded to hs-cTn results. We generated an adjusted hscTn rule-in cutoff to increase specificity.
RESULTS: 2505 subjects were enrolled; 234 were excluded. Patients were mostly male (55.7%) and white (57.2%), median age was 56 years 472 patients [20.8%] had an eGFR <60 mL/min/1.73 m2. In patients with eGFR <15 mL/min/1.73 m2, a baseline rule-in cutoff of 120 ng/L led to a specificity of 85.0% and Positive Predictive Value (PPV) of 62.5% with 774 patients requiring further observation. Increasing the cutoff to 600 ng/L increased specificity and PPV overall and in every eGFR subgroup (specificity and PPV 93.3% and 78.9%, respectively for eGFR <15 mL/min/1.73m(2)), while increasing the number (79) of patients requiring observation.
CONCLUSIONS: An eGFR-adjusted baseline rule-in threshold for the Siemens Atellica hs-cTnI improves specificity with identical sensitivity. Further study in a prospective cohort with higher rates of renal disease is warranted.
Medical Subject Headings
Aged; Algorithms; Biomarkers; Coronary Angiography; Electrocardiography; Female; Glomerular Filtration Rate; Humans; Male; Middle Aged; Non-ST Elevated Myocardial Infarction; Predictive Value of Tests; Prospective Studies; Renal Insufficiency, Chronic; Sensitivity and Specificity; Troponin I
PubMed ID
33071083
Volume
46
First Page
170
Last Page
175